Fulton County Pretreatment Services

Commercial Waste Discharge Permit Application

Apr 13, 2023
submission #665
Permit Information

Permit Information

Is this application for a New or Existing Permit (Renewal)? New

Facility Information

Name of Facility Stonehouse Tap
Facility Contact Name Rahul Patel
Facility Contact Phone Number +14044286323
Facility Physical Address 12595 Crabapple Rd, Alpharetta GA 30004-6629
Facility Contact Email Address [email protected]
Is Facility Mailing Address the same as above? Yes

Owner / Corporate Information

Owner / Corporation Name 12595 Crabapple LLC
Owner Contact Name Rahul Patel
Owner Contact Telephone ---
Owner Address ---

Commercial Waste Pretreatment System - Subsurface, exterior system

Do you have a Subsurface, exterior system? Yes

Exterior Tank #1

Trap #1 Type Grease Trap
Tank #1 Capacity 1000-1500
Do you have a second Subsurface, exterior system? No

Exterior Tank #2

Do you have a third Subsurface, exterior system? No

Commerical Waste Pretreatment System - Interior System

Do you have an interior PT system? No

Type of Business

Type of Business (restaurant, school, car maintenance) Restaurant
Has new equipment been added since business opened? No
Are your water and sewer provided by same jurisdiction? Yes, same jurisdiction

Utilities Jurisdiction

Water & Sewer Jurisdiction Fulton County

Commercial Waste Transporter Service (Pumper)

Company Name Dar Pro
F.O.G. Permit Number 001
Company Contact Name Ken Tomley
Company Address 5076 Nifda Dr SE, Atlanta GA 30339-1524
Company Telephone Number +18337311451

Waste Removal

Do you use a Grease/Waste Oil Recycle Company? Yes

Grease / Waste Oil Recycle Company

Company Name Dar Pro
Company Contact Name Ken Tomley
Company Address 5076 Nifda Dr SE, Atlanta GA 30339-1524
Company Telephone Number +18337311451
How often is recycled grease / oil waste removed? 1once a week
Container Capacity 300 Gallon

Maintenance Letter (Exterior 3 months)

Notarized Maintenance Letter upload 04082300.PDF

Service Agreement

Service Agreement Upload Dar Pro Agreement.pdf
Certification

Certification

Full Name Rahul Patel
Certification Yes
Verification & Permit Fee Calculation

Fee Calculation

How many subsurface system (exterior) tanks does the facility have? 1-5 ($250)
How many Manual (interior) 10-100 pound units does the facility have? 0
How many Automatic Grease Recovery 20-35 GPM units does the facility have? 0
Is the payment for the current year permit considered late? (RENEWALS ONLY: If today's date is prior to May 31, 2023, the answer should be no. If today's date is after May 31, 2023 the answer should be yes) No
Please enter how many years permit has been unpaid in the past (please enter 0 for none) (RENEWALS ONLY): 0